CAUTIONS AND PERSONAL SAFETY
- When using the hydraulic pump, always wear eye protection and gloves.
- Make sure that the hydraulic tensioner is bled of air before the first
operation and that the piston is in its bottom position before each operation.
- Use the correct oil as shown in Section 7 of the instructions.
- Use all equipment strictly in accordance with the instructions, or the
instructions supplied by the equipment manufacturer.
- Never exceed the specified oil pressure or the maximum stroke and oil
pressure stamped on the tensioner.
- All parts are marked with part numbers. It is imperative that the correct tool
accessories for each coupling is used. What tools to be used for each
coupling can be found on the assembly drawings.
- Inspect all equipment for damage before use.
- When releasing the sleeve expansion by oil injection, the nuts must not be
removed.
- As a further precaution, when mounting/dismounting the bolts, the area in
front of and behind the bolt must be kept clear of all personnel.